Quality Industrial Services Since 1950

J.M. Stuart Station and Killen Station (2400 MW & 615MW) - Dayton Power and Light

We perfomed surface preparation and exhaust duct interior lining for the FGD system at DP&L. The first step was initial decontamination and surface preparation using 40,000 p.s.i. Ultra High Pressure (UHP) water blasting to remove contaminants and provide a surface for abrasive blasting. Once we completed the UHP work, we used abrasive blasting to achieve a near-white grade surface.

We applied a high performance vinyl ester lining system at 40 mils, a 100 percent solids flake filled epoxy novolac at 60 mils, and a chopped glass reinforced epoxy novolac system at 120 mils.

In addition, we prepared and lined floors, concrete trenches and containment areas with a high-build elastomeric system. Because this phase of the work was critical to the project schedule, we used specialized climate control, heating and insulation methods to control the work environment.

Related Services

Project Photos

Dayton Power and Light
 
Dayton Power and Light
 
Dayton Power and Light